KOPRI Repository

Inter-laboratory comparison of stable carbon and nitrogen isotopic composition data using elemental analyzer-isotope ratio mass spectrometers

Cited 0 time in wos
Cited 0 time in scopus

Full metadata record

DC Field Value Language
dc.contributor.authorKim, Junghyun-
dc.contributor.authorKang, Sujin-
dc.contributor.authorBong, Yeon-Sik-
dc.contributor.authorPark, Kwangkyu-
dc.contributor.authorKang, Tae-Woo-
dc.contributor.authorPark, Yong-Se-
dc.contributor.authorKim, Dahae-
dc.contributor.authorChoi, Seunghyun-
dc.contributor.authorJoo, Young Ji-
dc.contributor.authorChoi, Bohyung-
dc.contributor.authorNam, Seung-il-
dc.contributor.authorLee, Sang-Mo-
dc.contributor.authorShin, Kyung-Hoon-
dc.date.accessioned2020-10-20T00:37:01Z-
dc.date.available2020-10-20T00:37:01Z-
dc.date.issued2018-12-
dc.identifier.urihttps://repository.kopri.re.kr/handle/201206/10863-
dc.description.abstractIn this study, inter-laboratory comparison was done using elemental analyzer-isotope ratio mass spectrometers (EA-IRMSs) to determine carbon and nitrogen contents as well as stable carbon and nitrogen isotopic compositions (δ13C and δ15N) of five environmental samples containing lake and marine sediments, higher plant leaves, and fish muscle, and one organic analytical standard (Protein (Casein) Standard OAS). Five national laboratories participated in this comparison study, and each laboratory analyzed all five samples and the analytical standard. Results showed that variations in total organic carbon (TOC) and total nitrogen (TN) contents as well as δ13CTOC and δ15NTN values among the laboratories were large compared to the analytical uncertainties. The results highlighted the inhomogeneity of the test samples and thus, the need to select suitable standard reference materials for future inter-laboratory studies. Further inter-laboratory comparison exercises could promote good measurement practices in the acquisition of stable carbon and nitrogen isotopic composition data.en_US
dc.languageEnglishen_US
dc.subjectChemistryen_US
dc.subject.classificationAraonen_US
dc.titleInter-laboratory comparison of stable carbon and nitrogen isotopic composition data using elemental analyzer-isotope ratio mass spectrometersen_US
dc.title.alternativeEA-IRMS를 활용한 탄소 및 질소 안정동위원소비 비교 연구en_US
dc.typeArticleen_US
dc.identifier.bibliographicCitationKim, Junghyun, et al. 2018. "Inter-laboratory comparison of stable carbon and nitrogen isotopic composition data using elemental analyzer-isotope ratio mass spectrometers". <em>JOURNAL OF ENVIRONMENTAL ANALYSIS, HEALTH AND TOXICOLOGY</em>, 21(4): 229-236.-
dc.citation.titleJOURNAL OF ENVIRONMENTAL ANALYSIS, HEALTH AND TOXICOLOGYen_US
dc.citation.volume21en_US
dc.citation.number4en_US
dc.identifier.doihttp://www.ksfea.or.kr/sub5_1.asp-
dc.citation.startPage229en_US
dc.citation.endPage236en_US
dc.description.articleClassificationKCI등재-
dc.description.jcrRateJCR 2016:0en_US
dc.subject.keywordinter-laboratory comparisonen_US
dc.subject.keywordstable carbon isotope (δ13C)en_US
dc.subject.keywordstable nitrogen isotope (δ15N)en_US
dc.identifier.localId2018-0375-
Appears in Collections  
2018-2019, Organic carbon transfer across the river-sea interface: a case study in Geum and Sumjin river systems (18-19) / Kim, Junghyun (PN18100)
Files in This Item

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse